The stepper motor is one of the most commonly used components when an axis needs to be positioned precisely without immediately resorting to a closed-loop system: packaging machines, dispensers, positioning tables, printers, laboratory equipment, and small- to medium-sized CNC axes. Choosing the right motor and driver prevents missed steps, overheating, and vibrations, and reduces commissioning times.
In this guide, we explain how a stepper motor works, what types exist, how to size it, how to match it with the driver, and what problems to check during installation.
What is a stepper motor?
A stepper motor is an electric motor that converts electrical pulses into rotations in fixed-size steps. Each pulse sent by the driver rotates the shaft by one step: the number of pulses determines the displacement, and their frequency determines the speed. The most common type has a step angle of 1.8°, i.e., 200 steps per revolution; there are high-resolution models of 0.9° (400 steps per revolution).
Differences compared to other motors
- DC motors: run continuously according to the applied voltage; an encoder and a control system are generally needed to know the position and speed. The difference between DC motors and stepper motors is therefore mainly the way position is controlled.
- AC motors: are designed for continuous operation, usually with mains or an inverter. For their use, see AC motors.
- Servomotors: operate in a closed loop with position feedback and are suitable for high dynamics and variable loads. Servomotors are generally more expensive, but they correct deviations in real time.
Advantages and limitations
The stepper motor offers repeatable open-loop positioning, holding torque, simple control with step and direction signals, and a robust structure. The limitations are the torque decreasing as speed increases, possible resonance at certain frequencies, and the fact that, in an open loop, the controller does not know if the motor has missed steps.
Types of stepper motors
The classification is based on two different levels: the rotor construction (for example, permanent magnet, variable reluctance, or hybrid) and the winding configuration (bipolar or unipolar). In industrial applications, hybrid motors are the most common and can be made with bipolar or unipolar windings. For a broader comparison, you can start from the stepper motors category and, for the general context, from that of electric motors.
Bipolar stepper motors
They have windings without a center tap: the current in the coil must be able to change direction, so the driver uses H bridges. Since they use the entire winding, they generally offer more torque for the same size. The driver is more complex than that of a unipolar, but modern bipolar drivers are very common and make this difference little relevant in practice.
Unipolar stepper motors
They have a center tap on each winding, which allows the magnetic field to be reversed without reversing the current: the drive circuit is simpler. Since only half the winding is powered at any given time, the torque for the same size is generally lower. Many 6-wire motors can also be connected as bipolar.
Hybrid stepper motors
They combine a permanent magnet rotor with teeth, and are the most common choice in automation for resolution and torque. They can be driven in full step, half step (which takes a 1.8° motor to 0.9°), or in microstepping.
In microstepping, the phases are not completely turned on or off, but powered with out-of-phase sinusoidal currents, and the rotor moves in micro-steps. The main advantage is the reduction of vibrations and smoother movement; the theoretical resolution increases, but the incremental torque per micro-step decreases, so the actual positioning accuracy also depends on the load and the mechanics.
How does a stepper motor work?
The stator has windings grouped into phases; the rotor has a permanent magnet and teeth. When the driver powers the phases in a precise sequence, the magnetic field of the stator rotates in jumps and the rotor follows it, step by step. The controller (PLC, positioning module, or microcontroller) sends two main signals to the driver: step and direction pulses. The driver converts these signals into currents in the windings, regulates the current, and protects the motor.
A brushed DC motor, on the other hand, runs as long as there is voltage and an external feedback loop is needed to position it. The stepper motor, under adequate load conditions, achieves positioning by counting the pulses.
How to choose the right stepper motor
Torque
The holding torque is the torque the motor produces from a standstill with the nominal current. The dynamic torque (or pull-out torque) is the maximum torque available at a given speed without losing synchronism, and it decreases as speed increases. For sizing, the resistive torque (friction, load, process forces), the torque needed to accelerate the inertia, and a safety margin must be considered. As a general indication, the required torque at the operating point should not approach the limit of the manufacturer's torque-speed curve.
Step angle and resolution
Steps per revolution are obtained as 360° divided by the step angle. A 1.8° motor has 200 steps per revolution; with 1/16 microstepping, you get 3,200 micro-steps per revolution. The linear displacement per step then depends on the transmission: for a 5 mm pitch screw, for example, 200 steps per revolution correspond to 0.025 mm per full step. To achieve excellent precision, the mechanics (play, elasticity) also count, not just the number of micro-steps.
Speed and acceleration
Torque-speed curves show how torque drops as the pulse frequency increases. An adequate acceleration ramp prevents losing synchronism. In dynamic applications, or with variable loads, it is advisable to evaluate solutions with encoders (closed loop) or servomotors.
Voltage and current
The key motor data are the nominal current per phase and the resistance and inductance of the windings. A higher driver supply voltage compared to the motor's nominal voltage allows maintaining torque at high speeds, provided the driver limits the current to the nominal value. The driver must be able to deliver the required current; the power supply must be sized accordingly.
Dimensions and mounting
Flange dimensions (for example, standardized NEMA formats, such as NEMA 17 or NEMA 23), shaft diameter and length, the presence of a brake or encoder, and the protection rating affect mounting. To adapt speed and torque to the application, gearboxes and other electric motor accessories can be used.
| Parameter | What to check | Risk if underestimated |
|---|---|---|
| Torque | Torque-speed curve, load, inertia, margin | Missed steps, stall |
| Step and resolution | Step angle, microstepping, transmission | Insufficient precision |
| Speed and acceleration | Ramps, resonances, maximum speed | Vibrations, loss of synchronism |
| Voltage and current | Current per phase, driver voltage, power supply | Overheating or reduced torque |
| Mechanics | Flange, shaft, fastening, protection | Mounting and reliability problems |
Drivers for stepper motors
Types of drivers
Drivers are distinguished by winding configuration (unipolar or bipolar), drive mode (full step, half step, microstepping), and control interface, with step and direction inputs or field communication. The most advanced models allow setting current, resolution, and current reduction at rest, and reporting overcurrent or overtemperature alarms. There are also systems with closed-loop control, which compare the requested position with the detected one and correct errors.
How to choose the right driver
- Motor compatibility: winding configuration and number of wires.
- Output current: compatible with the motor's nominal current per phase.
- Supply voltage: within the driver's allowed range, chosen based on the required speed.
- Control interface: step and direction signals, logic levels, and maximum accepted pulse frequency, compatible with the PLC or controller output.
For the set of drive and control components, you can consult the motor control category. For a specific motor-driver match, contact ELEXONIK indicating the brand, code, and application.
Applications of stepper motors
Where repeatable positioning with known loads and moderate dynamics is required, the stepper motor is a frequent choice:
- Machine automation: feeders, selectors, dispensers, precision conveyor belts, format positioning.
- Robotics and light handling: small linear and rotary axes.
- Small CNC and cutting machines: milling machine, plotter, and engraver axes.
- 3D printing and prototyping: XYZ axis and extruder movement.
- Laboratory and measuring equipment: dosing pumps, positioners.
For axes with a zero reference (homing) and end-of-stroke protection, proximity sensors and limit switches are normally used.
Motor integration into the system
Wiring and power supply
- Use cables suitable for the current and, where indicated by the manufacturer, shielded, with the shield connected according to the instructions, to limit interference on the step and direction signals.
- Keep the motor power cables separate from the signal cables.
- Do not connect or disconnect the motor with the driver powered: voltage spikes can damage the electronics.
- Size the power supply for the peak current and provide for the heat dissipation of the motor and the driver.
Control
The motor can be commanded by the step and direction signals of a PLC or a positioning module. For development systems and prototypes, microcontrollers are also often used, but in industrial applications, the management of ramps, limits, alarms, and interlocks is especially important, with the machine safety defined separately.
Common problems and how to address them
- Missed steps: often due to insufficient torque, too high acceleration, or excessive load. It is resolved by reviewing the ramps, the supply voltage, or the motor. In an open loop, the controller does not detect the error.
- Vibrations and resonance: can occur at certain speeds. They are reduced by avoiding that frequency, passing through it quickly, using half step or microstepping, or mechanical dampers.
- Overheating: check the set current, ventilation, and current reduction at rest.
- Irregular movements or noise: check the phase connection, wiring, and shielding.
- Motor not running: check power supply, driver enablement, step signals, and wire assignment.
If a motor or driver in service is discontinued, the page on industrial spare parts and components can be a starting point, while for a faulty device, the repair and technical assistance service is available.
In summary
The stepper motor is an effective and easy-to-control solution for positioning with known loads, provided that torque, speed, and power supply are properly sized and the correct driver is matched. If the dynamics are high or the load is variable, it is advisable to evaluate a closed loop or a servomotor. The manufacturer's data always remain the reference for final choices.